Best Roof Vents for Michigan Attics, Compared

In a Michigan attic, ventilation has two jobs: keep the roof deck cold in winter so snow doesn't melt and refreeze at the eaves, and carry off the moisture that leaks up from the house.

Here are the six kinds of roof and attic vents, ranked for how well they do those jobs here, with real product numbers from the companies that make them.

Schedule Your Free Roof Inspection

Facts checked September 22, 2026

Building Science Corporation puts it plainly: in cold climates, the main purpose of attic ventilation is to keep the roof cold to control ice dams and to vent moisture from the house. Every vent below is judged on that.

No single vent does the job alone. A ventilated attic needs intake low at the eaves and exhaust high near the ridge, sized to the attic and balanced. The manufacturers agree on the other big rule too: one type of exhaust vent per attic. So this list is less about picking a favorite and more about picking the right pair.

If you're chasing a symptom, like frost on the nails, ice dams or a hot upstairs, start with our roof ventilation problems page. This page compares the hardware.

How We Picked

How We Ranked the Vents

Even Airflow

A vent that pulls air along the whole underside of the roof beats one that vents a single spot and leaves hot or damp corners.

Snow and Weather

Baffles and filters that keep wind-driven rain and fine snow out. Unbaffled vents can let weather blow straight into the attic.

No Pull on the House

Exhaust that draws its make-up air from the soffits, not from the living space through gaps in the ceiling.

Net Free Area

The vent's rated open area, in square inches. It's the number the code and the manufacturers size an attic by.

Plays Well With Others

Works in a balanced system without short-circuiting. Some vents can't share an attic with others at all.

No Moving Parts

Passive vents have nothing to wear out or burn out. Motors need power, and without enough intake they work too hard.

The List

6 Attic Vent Types, Ranked for Michigan

  1. 1. Ridge Vent With a Baffle and Snow Filter

    Best for: The exhaust half of almost every shingle roof with a real ridge

    A continuous ridge vent exhausts along the peak, where the warmest, wettest air collects, and draws evenly from the whole length of the attic. Air Vent ranks ridge vents as the best attic exhaust, ahead of power vents, turbines and louvers. The full-width baffled models from GAF, Air Vent, CertainTeed and Lomanco are each rated at 18 square inches of net free area per linear foot.

    For Michigan, look for two features. An external baffle deflects wind so it pulls air out of the attic instead of blowing in; Air Vent warns that unbaffled ridge vents can let weather in and let strong wind pass straight through. And a snow filter: GAF's Cobra SnowCountry models carry a Snow Guard filter, Air Vent says ShingleVent II's internal filter helps trap fine snow, and CertainTeed's filtered ridge vent has an internal weather filter against windblown snow.

    Rolled ridge vents are a lower-profile option with less airflow per foot: 12 square inches for CertainTeed's Rolled Ridge Vent and Air Vent's Peak Performer, 14.1 to 16.9 for GAF's original Cobra roll depending on the version.

    • 18 sq. in. NFA per foot: GAF Cobra SnowCountry Advanced, Air Vent ShingleVent II, CertainTeed 12 in. Filtered, Lomanco OmniRidge
    • GAF and Air Vent list 3:12 to 16:12 slopes for these models
    • Air Vent: 42 ft of ridge vent equals five turbines or 15 roof louvers
  2. 2. Soffit and Other Intake Vents

    Best for: Every vented attic. Exhaust only works as well as the intake that feeds it

    Intake isn't an alternative to a ridge vent. It's the other half of it. GAF calls intake arguably the most important part of attic ventilation, and Air Vent says you cannot have too much of it: extra intake on the downwind side simply switches to exhaust. Too much exhaust is the problem, because the vents then pull make-up air from wherever they can.

    Continuous soffit vents are rated at 9 square inches per foot in Air Vent's literature, and CertainTeed says its Triple 3-1/3 in. InvisiVent vinyl soffit gives more than 10 square inches of net free intake area. Houses with little or no overhang can use a roof-edge intake instead: Air Vent's The Edge Vent and CertainTeed's Intake Vent are both rated at 9 square inches per foot, and CertainTeed's needs at least a 3:12 pitch.

    Intake only works if it's open. Insulation pushed over the soffits blocks it, which is what rafter baffles are for.

    • Continuous soffit vent: 9 sq. in. NFA per foot (Air Vent)
    • CertainTeed Intake Vent: 9 sq. in. per foot, 3:12 minimum pitch
    • Air Vent: "You cannot have too much intake ventilation"
  3. 3. Box Vents (Roof Louvers)

    Best for: Roofs without enough ridge length for a ridge vent

    Box vents are fixed, passive, and simple. The catch is that each one vents a single spot, so they need to be spread and sized correctly, and Air Vent puts them in its "good" tier with turbines and gable louvers because they depend on wind direction and can leave hot spots.

    Sizes vary. GAF's Master Flow IR65 is rated at 65 square inches of net free area, which GAF says is 30% more than a typical 50-square-inch box vent. Air Vent recommends keeping box vents on the same side of the roof over a common attic; otherwise, depending on the wind, one side can act as intake for the other and draw in weather.

    • GAF Master Flow IR65: 65 sq. in. NFA per vent
    • Typical box vent: 50 sq. in. NFA (GAF)
    • Keep them on one side of the roof over a common attic
  4. 4. Gable Vents

    Best for: Older houses that already have them and no ridge vent

    Gable louvers sit in the end walls, so they add no holes in the roof. Air Vent rates them "good" alongside box vents and turbines, because louvers depend on wind direction and vent only one area of the attic.

    The rule that matters in a replacement: if the new roof gets a ridge vent, the gable vents should be closed off. Air Vent says left open, they become intake for the ridge vent, which risks weather getting in and poor airflow through the rest of the attic.

    • Air Vent tier: good
    • Close them off when a ridge vent goes in
  5. 5. Wind Turbines

    Best for: Roofs that need a lot of exhaust from a few openings

    Turbines move a lot of air per opening when the wind blows. Air Vent rates its 12-inch turbine at 95 square inches of net free area and its 14-inch at 132, with an adjustable base for 3:12 to 12:12 pitches.

    They share the weaknesses of box vents: each one is a single spot, performance depends on the wind, and Air Vent keeps them in its "good" tier. Like box vents, they belong on one side of the roof over a common attic, and never on a roof that also has a ridge vent.

    • Air Vent 12 in. turbine: 95 sq. in. NFA; 14 in.: 132 sq. in.
    • Adjustable base for 3:12 to 12:12
  6. 6. Powered Attic Fans

    Best for: Rarely the right call in a Michigan attic

    Air Vent ranks power vents above turbines and louvers. We rank them last for Michigan, because the U.S. Department of Energy's Building America Solution Center is blunt about them: attic fans create negative pressure that draws conditioned air out of the house through gaps in the ceiling, can make combustion appliances draft poorly or backdraft, and in winter pull warm, moist air into the attic. DOE says studies show they often cause more overall energy loss than they save and can increase moisture problems in winter, and notes they are not recommended by ENERGY STAR.

    If one is used, it needs intake to match. Air Vent sizes a power vent at the attic's square footage times 0.7 for the minimum CFM, then divides the CFM by 300 for the square feet of intake; a 1,500-square-foot attic needs a 1,050 CFM fan and about 504 square inches of intake. GAF's Master Flow roof-mount fans include an adjustable thermostat with an optional humidistat. A power fan should never share an attic with a ridge vent.

    • DOE: often cause more energy loss than they save
    • Air Vent sizing: attic sq. ft. x 0.7 = minimum CFM
    • Intake needed: CFM / 300 = sq. ft. of intake
Side by Side

Attic Vents by the Numbers

VentExample productsNet free areaPitch rangeAir Vent tier
Ridge vent, 12 in. baffledGAF Cobra SnowCountry Advanced, Air Vent ShingleVent II, CertainTeed 12 in. Filtered, Lomanco OmniRidge18 sq. in. per ft3:12 to 16:12*Best
Ridge vent, narrow or low-profileCertainTeed 9 in., Air Vent ShingleVent II-9, Lomanco Lo-OmniRidge11 to 16 sq. in. per ft3:12 to 12:12 (Air Vent, CertainTeed)Best
Rolled ridge ventGAF Cobra (original roll), CertainTeed Rolled Ridge Vent, Air Vent Peak Performer12 to 16.9 sq. in. per ft2:12 to 20:12 (GAF); 3:12 to 12:12 (CertainTeed)Best
Soffit and edge intakeContinuous soffit vent, Air Vent The Edge Vent, CertainTeed Intake Vent9 sq. in. per ftIntake Vent: 3:12 minimumIntake
Box vent (roof louver)GAF Master Flow IR6565 sq. in. each (typical: 50)Varies by productGood
Wind turbineAir Vent 12 in. and 14 in.95 or 132 sq. in. each3:12 to 12:12Good
Gable louverWall-mounted, variousVariesNot on the roofGood
Powered attic fanGAF Master Flow ERV seriesSized by CFMVaries by productBetter (we rank it last)

Figures are each manufacturer's published ratings. * CertainTeed's 2025 brochure lists its 12 in. ridge vents at 3:12 to 12:12, while an older data sheet for the filtered model says 3:12 to 16:12. Check the current installation instructions for your product.

Sizing

Five Rules for a Balanced Attic

Michigan's residential code is still based on the 2015 International Residential Code; the 2021 edition is on hold under a July 2025 court order. Its ventilation section, R806.2, is where the sizing starts. Our roof ventilation problems page covers how to tell if yours falls short. These are the rules for choosing and sizing the vents themselves.

  1. 01. Start at 1/150

    The 2015 code requires net free vent area of at least 1/150 of the vented attic space. It allows 1/300 when one or more of two conditions are met: a Class I or II vapor retarder on the warm side of the ceiling in climate zones 6 to 8, or 40 to 50% of the vent area placed within 3 feet of the ridge with the rest at the eaves. Kent, Ottawa, Allegan, Muskegon and Ionia counties are climate zone 5A, so the vapor retarder route doesn't apply there.

  2. 02. Split it 50/50

    Air Vent's rule is to balance attic ventilation 50% intake and 50% exhaust. GAF puts it on every Cobra ridge vent page: in no case should ridge exhaust exceed soffit intake. If you're short, add intake, which ARMA also recommends for boosting a passive system.

  3. 03. One exhaust type per attic

    Air Vent says it is never OK to mix two types of exhaust vents over a common attic. Ridge vents, turbines, box vents, gable louvers and power fans each count as a type. Mixed, one exhaust vent turns into intake for the other, parts of the attic go unvented, and weather can get in. GAF and ARMA say the same.

  4. 04. Cut the ridge slot to fit

    A ridge vent can run the full ridge for looks, but GAF says to cut the slot only as long as needed. Its example: 288 square inches of required exhaust at 18 square inches per foot is 16 feet of slot on a 40-foot ridge, balanced with the same amount of intake.

  5. 05. Seal the ceiling first

    Building Science Corporation says a vented attic shouldn't communicate with the house. DOE's Building America Solution Center says to air seal the ceiling first, and warns that more passive ventilation can make moisture worse if the ceiling isn't sealed.

Next Step

Get the Ventilation Right With the New Roof

We correct the attic ventilation on every roof we replace, because it's the cheapest time to do it: the roof is already open. Our free inspection covers the attic as well as the roof, with photos and a written report.

Plan Your Roof Replacement
FAQ

Best Roof Vents for Michigan Attics, Compared: FAQ

What is the best roof vent for a Michigan home?

For most shingle roofs, a baffled, filtered ridge vent paired with enough soffit intake to match it. Air Vent ranks ridge vents as the best exhaust, and in a snowy climate the baffle and filter help keep wind-driven snow out. Where there isn't enough ridge for a ridge vent, correctly sized box vents on one side of the roof are the next choice.

Can I have a ridge vent and box vents or gable vents on the same roof?

Not over the same attic. Air Vent, GAF and ARMA all advise against mixing exhaust types, because one vent ends up pulling air through the other instead of from the soffits. When a ridge vent goes in, gable vents should be closed off and box vents removed.

Is a power attic fan a good idea in Michigan?

Usually not. The DOE Building America Solution Center says attic fans can pull conditioned air out of the house, can cause combustion appliances to backdraft, and in winter pull warm, moist air into the attic. Studies show they often cause more energy loss than they save. Balanced passive ventilation and a sealed ceiling are the better fix.

How much attic ventilation do I need?

Under Michigan's current code, based on the 2015 IRC, at least 1 square foot of net free vent area for every 150 square feet of attic, or 1 per 300 when the code's exception applies. A 1,500-square-foot attic at 1/150 needs 10 square feet, or 1,440 square inches. Air Vent recommends splitting it evenly between intake and exhaust.

Do ridge vents let snow into the attic?

Unbaffled ones can. That's why snow-country models add filters: GAF's Cobra SnowCountry vents carry a Snow Guard filter, and Air Vent says ShingleVent II's internal filter helps trap fine snow. Air Vent says the University of Minnesota ran snow-infiltration tests on ShingleVent II, though the report isn't public.

Will you fix my ventilation when you replace my roof?

Yes. We correct the ventilation on every roof we replace.

Sources

What This Page Cites

  • GAF, product pages for Cobra SnowCountry Advanced, Cobra SnowCountry, Cobra Rigid Vent 3 and Cobra Exhaust Vent for Roof Ridge; Master Flow Roof Louver IR65; Master Flow roof-mount power attic vents, gaf.com.
  • GAF blog, "5 Common Installation Mistakes When Venting Attics," gaf.com.
  • CertainTeed, Ventilation brochure (October 2025), 12 in. Filtered Ridge Vent technical data sheet, Ridge Vent and Rolled Ridge Vent product pages, certainteed.com.
  • Air Vent (Gibraltar Building Products), ShingleVent II sell sheet; Ridge Vent Systems (AVI023); 2024 Air Vent catalog; Power Vents sell sheet (2026).
  • Air Vent knowledge base, help.gibraltarbuildingproducts.com: ranking exhaust vents; mixing exhaust vents; power fans with ridge vents; gable vents with ridge vents; too much exhaust; too much intake; roof louvers on multiple sides; ShingleVent II in snow climates.
  • Lomanco, Ridge Vents product page, lomanco.com.
  • International Code Council, 2015 International Residential Code, Section R806.2; 2021 International Energy Conservation Code, climate zone table.
  • Michigan LARA Bureau of Construction Codes, notice of the July 7, 2025 Court of Claims order on the 2021 residential and energy codes.
  • Asphalt Roofing Manufacturers Association, "Installing Attic Ventilation," asphaltroofing.org.
  • U.S. DOE Building America Solution Center (PNNL), "Attic Ventilation Fans"; ENERGY STAR, "About Attic Ventilation."
  • Building Science Corporation, BSD-102: Understanding Attic Ventilation.
  • Florida Solar Energy Center, FSEC-GP-171-00, on powered attic ventilation.